Side by side
| LVL | Steel (W-shape or I-beam) | Built-up lumber | |
|---|---|---|---|
| Strength for its depth | Good | Highest | Lowest |
| Weight | Light to moderate | Heavy | Moderate |
| Fastening joists | Nail and hang directly | Wood nailer or bearing on the flange | Nail and hang directly |
| Typical use | Wall openings, girders, ridge beams | Long flush spans, tight headroom | Short headers |
| Getting it into the house | Usually by hand, in plies | Often extra crew or equipment | By hand |
| Installed cost | About $50–$200 per linear ft (Angi) | About $100–$400 per linear ft (Angi) | Lowest for short spans |
When steel earns its cost
- A long flush beam in an open kitchen where a dropped beam would hit the ceiling.
- Low basement headroom where a deep wood beam would be in the way.
- Very heavy loads, such as a second story plus roof landing on one beam.
When LVL is the better choice
- Most bearing wall removals with moderate spans. See load-bearing wall removal.
- Main beam replacements in basements, where lighter plies can be carried in and fastened together on site. See beam replacement.
- Dormers and second stories, for ridge beams and headers.
What the code and the engineer decide
New York’s 2025 Residential Code has header tables for ordinary window and door openings in walls (2025 RCNYS, chapter 6). Beams that replace bearing walls or carry concentrated loads usually go beyond those tables, so expect an engineer to specify size, material, bearing length, posts and connections. Every post has to carry its load down to a footing.
Cost
Angi’s 2026 figures put an LVL beam installation at $1,500 to $4,000, averaging $2,500, and compare $50 to $200 per linear foot for LVL against $100 to $400 for a steel I-beam (Angi). Full breakdowns: beam replacement cost and wall removal cost.
Frequently asked questions
What size LVL beam do I need?
That depends on the span, what the beam carries (a ceiling, a floor, a roof, or a wall above) and the deflection limit. Manufacturer span tables give a starting point, but for removing a bearing wall or replacing a main beam, towns typically expect an engineer's calculation.
Is steel always stronger than LVL?
For the same depth, steel carries much more load, which is why it's chosen for long flush beams or tight headroom. But a deeper or multi-ply LVL often does the same job with simpler installation. The engineer weighs depth, weight and connections.
Can I nail joists to a steel beam?
Not directly. Steel beams usually get a wood nailer bolted to the top or sides so joists and hangers can be fastened, or joists bear on the bottom flange with blocking. Those details should be on the engineer's drawing.
What about glulam or built-up 2x lumber?
Glulam is engineered wood that can be exposed as a finished beam and handles long spans. Built-up dimensional lumber is fine for short headers. LVL sits between them for most hidden structural beams in houses.